Test R: The RH Turn Indicator Is Never on

PINPOINT TEST R: THE RH TURN INDICATOR IS NEVER ON


R1-R3:






R3-R4:






Normal Operation
The RH turn indicator bulb is powered through circuit 1392 (LG/OG) when the multifunction switch is placed in the RH turn signal position. The RH turn indicator bulb is grounded through the instrument cluster bulb ground circuit 1205 (BK).

Possible Causes
- circuit 1205 (BK) open
- circuit 1392 (LG/OG) open
- multifunction switch
- instrument cluster