Operation CHARM: Car repair manuals for everyone.

Pinpoint Test W: The High Beam Indicator Is Never/Always On




Instrumentation, Message Center and Warning Chimes

Pinpoint Tests

Pinpoint Test W: The High Beam Indicator Is Never/Always On

Normal Operation

When the high beams are turned on, the Smart Junction Box (SJB) sends a signal to the Instrument Cluster (IC) through the Medium Speed Controller Area Network (MS-CAN) communication bus to illuminate the high beam indicator. If the high beam status message is missing for more than 5 seconds, the IC sets DTC U0140 in continuous memory and defaults the high beam indicator off.

NOTE: If DTC U0140 is set in the IC, other observable symptoms may also be present such as Tire Pressure Monitoring System (TPMS) warning indicator, backlighting and door ajar indication.

This pinpoint test is intended to diagnose the following:

- SJB
- IC



PINPOINT TEST W: THE HIGH BEAM INDICATOR IS NEVER/ALWAYS ON

-------------------------------------------------
W1 CHECK THE HIGH BEAM HEADLAMPS OPERATION


- Turn the headlamps in the HIGH BEAM position. Observe the high beam headlamps.
- Do the high beam headlamps operate correctly?

Yes
GO to W2.

No
REFER to Headlamp. Headlamp

-------------------------------------------------
W2 CARRY OUT THE IC INDICATOR LAMP CONTROL ACTIVE COMMAND USING THE SCAN TOOL


- Ignition ON.
- Enter the following diagnostic mode on the scan tool: IC DataLogger.
- Select the IC high beam indicator (HIGH_BEAM). Command the high beam indicator on and off. Observe the high beam indicator.
- Does the high beam indicator illuminate when commanded on, and turn off when commanded off?

Yes
GO to W3.

No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.

-------------------------------------------------
W3 RETRIEVE THE RECORDED DTCs FROM THE IC SELF-TEST


- Check for recorded IC DTCs from the self-test.
- Is DTC U0140 recorded?

Yes
Go To Pinpoint Test AZ. Pinpoint Tests AZ: DTC U0140

No
INSTALL a new Smart Junction Box (SJB). TEST the system for normal operation.

-------------------------------------------------