Operation CHARM: Car repair manuals for everyone.

Air Flow Meter/Sensor: Specifications

OUTPUT FREQUENCY
(Reading taken using scan tool)
At 700 RPM 25 - 45 Hertz
At 2,000 RPM 70 - 90 Hertz
Racing engine should increase the frequency

VOLTAGE SPECIFICATIONS
Terminal 4 System Voltage
Terminal 3 4.8 - 5.2 Volts