Operation CHARM: Car repair manuals for everyone.

Exhaust Manifold and Water Pump






REMOVAL AND INSTALLATION

INSTALLATION SERVICE POINT
]A[ WATER OUTLET FITTING INSTALLATION

NOTE: After installation, keep the sealed area away from the coolant for approximately one hour.





1. Apply a 3 mm (0.1 inch) diameter bead of sealant. (Mitsubishi Genuine Part number MD970389) to the groove as shown in the illustration.
2. Install the housing quickly while the sealant is wet (within 15 minutes).