Service Specifications

Basic Ignition Timing At Idle Standard value 5 degrees BTDC +/- 3 degrees
Actual Ignition Timing At Idle Standard value Approximately 15 degrees BTDC
CO content Standard value 0.5 % or less
HC contents ppm Standard value 100 ppm or less
Curb idle speed Standard value 700 +/- 100 r/min
Compression pressure
(250 - 400 r/min)
Standard value 824 kPa
Limit Minimum 575 kPa
Compression Pressure Difference Of All Cylinder Standard value 98 kPa
Intake Manifold Vacuum At Curb Idle Limit Minimum 60 kPa
Auto-Tensioner Pushrod Movement Standard value Within 1.0 mm
Auto-Tensioner Rod Protrusion Standard value 3.8 - 5.0 mm