Electrical Specifications

SERVICE SPECIFICATIONS

EMISSION CONTROL SYSTEM

ITEM STANDARD VALUE
Purge flow [at 80 - 95 °C (176 - 205 °F) with sudden revving] 20 cu.cm/s (2.5 SCFH)
Evaporative emission purge solenoid coil resistance [at 20 °C (68 °F)] 22 - 26 Ohms
EGR valve (Stepper Motor) connector resistance [at 20 °C (68 °F)] 20 - 24 Ohms
Evaporative emission ventilation solenoid coil resistance [at 20 °C (68 °F)] 17 - 21 Ohms