Troubleshooting Guide
TROUBLESHOOTING GUIDEThe charging system troubleshooting guide is shown in the following steps.
STEP 1.
Q: Is the battery in good condition? (Refer to Chassis Electrical - Battery - On-vehicle Service - Battery Check)
YES: Go to Step 2.
NO: Charge or replace the battery.
STEP 2.
Q: Is the generator drive belt in good condition? (Refer to General - Maintenance Service - Drive Belts (For Generator, Power Steering Pump and Air Conditioning) (Check))
YES: Go to Step 3.
NO: Adjust the belt tension or replace the belt.
STEP 3.
Q: Does the generator malfunction light come on when the ignition switch is turned on?
YES: Go to Step 4.
NO:
- Check the ignition switch. (Refer to Chassis Electrical - Ignition Switch - Ignition Switch - Inspection.)
- Check for burnt-out generator malfunction light.
- Check the generator. (Refer to Charging System - Generator Assembly - Inspection.)
- Check the generator malfunction light-related circuits.
STEP 4.
Q: Does the generator malfunction light go out after starting the engine?
YES: Go to Step 5.
NO: Check the generator (Refer to Charging System - Generator Assembly - Inspection.)
STEP 5.
Q: Is an oscilloscope available?
YES: Go to Step 6.
NO: Go to Step 7.
STEP 6.
Q: Dose the oscilloscope show a normal wave pattern? (Refer to Charging System - On-vehicle Service - Wave Pattern Check Using an Oscilloscope.) Oscilloscope Patterns and Waveforms
YES: Go to Step 7.
NO: Check the generator. (Refer to Charging System - Generator Assembly - Inspection.)
STEP 7.
- Engine: 2,500 r/min
- Headlight: ON (high beam)
- Voltage between generator terminal B and the positive battery terminal
OK: 0.5 V or less
- Voltage between the negative battery terminal and generator body
OK: 0.5 V or less
Q: Are the generator output line and ground line in good condition?
YES: Go to Step 8.
NO: Check the generator output line and ground line.
STEP 8.
Q: Is the output current normal? (Refer to Charging System - On-vehicle Service - Output Current Test.) Output Current Test
YES: Go to Step 9.
NO: Check the generator (Refer to Charging System - Generator Assembly - Inspection.)
STEP 9.
Q: Is the regulated voltage normal? (Refer to Charging System - On-vehicle Service - Regulated Voltage Test.) Regulated Voltage Test
YES: Go to Step 10.
NO: Check the generator (Refer to Charging System - Generator Assembly - Inspection.)
STEP 10.
Q: Is the voltage drop in the generator output line normal?
YES: Generator is normal. Check other systems.
NO: Check the output line.