Operation CHARM: Car repair manuals for everyone.

Pressure Regulating Solenoid: Testing and Inspection




SOLENOID VALVE CHECK





1. Disconnect the CVT assembly connector.
2. Measure the resistance between the terminals of the applicable solenoid valves and ground.
Standard value:





3. When the resistance is within the standard value, check the power supply and the ground circuits.
4.
CAUTION:
Each solenoid valve cannot be removed or replaced as a single unit. When replacement of any one of the solenoid valves is necessary, replace the valve body assembly.

When the resistance is outside the standard value, replace the valve body assembly and the harness.