Warning Chime System
FUNCTION DIAGNOSISWARNING CHIME SYSTEM
WARNING CHIME SYSTEM : System Diagram
WARNING CHIME SYSTEM : System Description
COMBINATION METER
- The buzzer for warning chime system is installed in the combination meter.
- The buzzer sounds when the combination meter receives a buzzer output signal from each unit.
BCM
BCM receives signals from various units and transmits a buzzer output signal to the combination meter with CAN communication line if it judges that the warning buzzer should be activated.
BCM warning function list
WARNING CHIME SYSTEM : Component Description