Initial Inspection and Diagnostic Overview
IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM)
IPDM E/R Power/Ground Circuit Inspection
1.FUSE AND FUSIBLE LINK INSPECTION
Check that the following fusible links or IPDM E/R fuses are not blown.
OK or NG
OK - GO TO 2.
NG - Replace fuse or fusible link.
2.POWER CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E120.
3. Check voltage between IPDM E/R harness connector E120 terminals 1, 2 and ground.
Battery voltage should exist.
OK or NG
OK - GO TO 3.
NG - Repair or replace IPDM E/R power circuit harness.
3.GROUND CIRCUIT INSPECTION
1. Disconnect IPDM E/R harness connectors E121 and E124.
2. Check continuity between IPDM E/R harness connector E121(A) terminal 60, E124(B) terminal 38 and ground.
Continuity should exist.
OK or NG
OK - Inspection End.
NG - Repair or replace IPDM E/R ground circuit harness.