Operation CHARM: Car repair manuals for everyone.

Intelligent Key Unit





POWER SUPPLY AND GROUND CIRCUIT


INTELLIGENT KEY UNIT : Diagnosis Procedure

Regarding Wiring Diagram information, Intelligent Key Unit.

1.CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.





2. Disconnect Intelligent Key unit connector.
3. Check voltage between Intelligent Key unit harness connector
M70 terminals 6, 11 and ground.





Is the inspection result normal?
YES - GO TO 2
NO - Repair or replace Intelligent Key power supply circuit.
2.CHECK GROUND CIRCUIT





Check continuity between Intelligent Key unit harness connector
M70 terminal 12 and ground.

12 - Ground : Continuity should exist.

Is the inspection result normal?
YES - Power supply and ground circuits are OK.
NO - Repair or replace the Intelligent Key unit ground circuit.