Component Inspection
VDC OFF SWITCH
Component Inspection
1.CHECK VDC OFF SWITCH
1. Turn ignition switch OFF.
2. Disconnect VDC OFF switch connector.
3. Check continuity between VDC OFF switch connector terminals.
Is the inspection result normal?
YES - INSPECTION END
NO - Replace VDC OFF switch.