Operation CHARM: Car repair manuals for everyone.

For California





REFRIGERANT PRESSURE SENSOR


Description

The refrigerant pressure sensor is installed at the condenser of the air conditioner system. The sensor uses an electrostatic volume pressure transducer to convert refrigerant pressure to voltage. The voltage signal is sent to ECM, and ECM controls cooling fan system.









REFRIGERANT PRESSURE SENSOR


Diagnosis Procedure

1.CHECK GROUND CONNECTION
1. Turn A/C switch and blower fan switch OFF.
2. Stop engine.
3. Turn ignition switch OFF.
4. Check ground connection E21. Refer to Ground Inspection in Circuit Inspection.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace ground connection.
2.CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Disconnect refrigerant pressure sensor harness connector.
2. Turn ignition switch ON.
3. Check the voltage between refrigerant pressure sensor harness connector and ground.





Is the inspection result normal?
YES - GO TO 4.
NO - GO TO 3.
3.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F123, E6
- Harness for open or short between ECM and refrigerant pressure sensor
- Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.





4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES - GO TO 6.
NO - GO TO 5.
5.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F123, E6
- Harness for open or short between ECM and refrigerant pressure sensor
- Repair open circuit or short to ground or short to power in harness or connectors.
6.CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check the continuity between ECM harness connector and refrigerant pressure sensor harness connector.





2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES - GO TO 8.
NO - GO TO 7.
7.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F123, E6
- Harness for open or short between ECM and refrigerant pressure sensor
- Repair open circuit or short to ground or short to power in harness or connectors.
8.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
Is the inspection result normal?
YES - Replace refrigerant pressure sensor.