On Board Diagnostic (OBD) System
ON BOARD DIAGNOSTIC (OBD) SYSTEM
Trouble Diagnosis without CONSULT
DIAGNOSTIC PROCEDURE 6
Inspect SRS Malfunction Using "AIR BAG" Warning Lamp-Diagnosis Mode
NOTE:
SRS will not enter Diagnosis mode if no malfunction is detected in User mode.
1.Turn ignition switch ON.
2.After "AIR BAG" warning lamp lights for 7 seconds, turn ignition switch OFF within 1 second.
3.Wait more than 3 seconds.
4.Repeat steps 1 to 3 two more times (3 times total).
5.Turn ignition switch ON.
SRS is now in Diagnosis mode. Trouble Diagnosis Without CONSULT.