Diagnosis Procedure
POWER SUPPLY AND GROUND CIRCUIT
POWER WINDOW MAIN SWITCH : Diagnosis Procedure
Regarding Wiring Diagram information, [1][2]Electrical Diagrams.
1. CHECK POWER SUPPLY CIRCUIT
1.Turn ignition switch ON.
2.Check voltage between main power window and door lock/
unlock switch connectors (A and B) and ground.
Is the measurement value within the specification?
YES- GO TO 3
NO- GO TO 2
2. CHECK HARNESS CONTINUITY
1.Turn ignition switch OFF.
2.Disconnect BCM, main power window and door lock/unlock switch, power window and door lock/unlock switch RH, rear power window switch LH and rear power window switch RH.
3.Check continuity between BCM connector (A) and main power window and door lock/unlock switch connectors (B and C).
4.Check continuity between BCM connector (A) and ground.
Is the inspection result normal?
YES- GO TO 4
NO- Repair or replace harness.
3. CHECK GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect main power window and door lock/unlock switch.
3.Check continuity between main power window and door lock/
unlock switch connector and ground.
Is the inspection result normal?
YES- Check main power window and door lock/unlock switch output signal (rear power window switch LH) GO TO 5
YES- Check main power window and door lock/unlock switch output signal (rear power window switch
RH) GO TO 6
YES- Check main power window and door lock/unlock switch output signal (front power window switch
LH) GO TO 7
NO- Repair or replace harness.
4. CHECK BCM OUTPUT SIGNAL
1.Connect BCM.
2.Turn ignition switch ON.
3.Check voltage between BCM connector and ground.
Is the measurement value within the specification?
YES- Check intermittent incident. Intermittent Incident.
NO- Replace BCM. Service and Repair.
5. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (REAR POWER WINDOW SWITCH LH)
1.Connect main power window and door lock/unlock switch.
2.Turn ignition switch ON.
3.Check voltage between main power window and door lock/unlock switch connector and ground.
Is the measurement value within the specification?
YES- Check intermittent incident. Intermittent Incident.
NO- Replace main power window and door lock/unlock switch. Power Window Main Switch.
6. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (REAR POWER WINDOW SWITCH RH)
1.Connect main power window and door lock/unlock switch.
2.Turn ignition switch ON.
3.Check voltage between main power window and door lock/unlock switch connector and ground.
Is the measurement value within the specification?
YES- Check intermittent incident. Intermittent Incident.
NO- Replace main power window and door lock/unlock switch. Power Window Main Switch.
7. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (FRONT POWER WINDOW SWITCH LH)
1.Connect main power window and door lock/unlock switch.
2.Turn ignition switch ON.
3.Check voltage between main power window and door lock/unlock switch connector and ground.
Is the measurement value within the specification?
YES- Check intermittent incident. Intermittent Incident.
NO- Replace main power window and door lock/unlock switch. Power Window Main Switch.