Displaying and Reading Trouble Codes
How to Display and Read Diagnostic Trouble Codes
Using the Warning Lamp
Self-diagnosis results can be also read by using the "AIR BAG" warning lamp.
The "Air bag" warning lamp operates as shown below:
- Problem codes are displayed in present diagnosis mode (self-diagnosis result 1).
- The problem code last indicated is displayed in initial diagnosis mode (self-diagnosis result 2).
- After the malfunctioning parts have been repaired and the system is returned to the user mode, the present diagnosis mode information, displayed as self-diagnosis results, is automatically cleared from memory.
- After repairing malfunctioning part, attempt to clear self-diagnosis results from memory.
- If a malfunctioning part is not completely repaired, information stored in memory will not be cleared.
Warning Lamp Flashing Times And Repair:
WARNING LAMP FLASH CODE CHART
NOTE:
Self-diagnosis results in present- and initial-diagnosis modes can be identified by number of flashes �. Refer to Table for troubled parts.