P0442
P0442 EVAP Control SystemOn Board Diagnosis Logic
NOTE: If DTC P0442 is displayed with P1448, perform trouble diagnosis for DTC P1448 first.
This diagnosis detects leaks in the EVAP purge line using engine intake manifold vacuum.
If pressure does not increase, the ECM will check for leaks in the line between the fuel tank and EVAP canister purge volume control solenoid valve, under the following "Vacuum test" conditions. The vacuum cut valve bypass valve is opened to clear the line between the fuel tank and the EVAP canister purge volume control solenoid valve. The EVAP canister vent control valve will then be closed to shut the EVAP purge line off. The EVAP canister purge volume control solenoid valve is opened to depressurize the EVAP purge line using intake manifold vacuum. After this occurs, the EVAP canister purge volume control solenoid valve will be closed.
Malfunction is detected when EVAP control system has a leak, EVAP control system does not operate properly.
CAUTION:
- Use only a genuine NISSAN fuel filler cap as a replacement. If an incorrect fuel filler cap is used, the MIL may come on.
- If the fuel filler cap is not tightened properly, the MIL may come on.
- Use only a genuine NISSAN rubber tube as a replacement.
POSSIBLE CAUSE
- Incorrect fuel tank vacuum relief valve
- Incorrect fuel filler cap used
- Fuel filler cap remains open or fails to close.
- Foreign matter caught in fuel filler cap.
- Leak is in line between intake manifold and EVAP canister purge volume control solenoid valve.
- Foreign matter caught in EVAP canister vent control valve.
- EVAP canister or fuel tank leaks
- EVAP purge line (pipe and rubber tube) leaks
- EVAP purge line rubber tube bent.
- Blocked or bent rubber tube to EVAP control system pressure sensor
- Loose or disconnected rubber tube
- EVAP canister vent control valve and the circuit
- EVAP canister purge volume control solenoid valve and the circuit
- Fuel tank temperature sensor
- O-ring of EVAP canister vent control valve is missing or damaged.
- Water separator
- EVAP canister is saturated with water.
- EVAP control system pressure sensor
- Fuel level sensor and the circuit.
- Refueling EVAP vapor cut
- ORVR system leaks
DTC Confirmation Procedure
NOTE:
- If DTC P0442 is displayed with P1448, perform trouble diagnosis for DTC P1448 first.
- If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch OFF and wait at least 5 seconds before conducting the next test.
TESTING CONDITION:
- Perform "DTC WORK SUPPORT" when the fuel level is between 1/4 to 3/4 full and vehicle is placed on flat level surface.
- Open engine hood before conducting the following procedure.
With CONSULT-II
1. Turn ignition switch ON.
2. Turn ignition switch OFF and wait at least 5 seconds.
3. Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT-II.
4. Make sure that the following conditions are met.
COOLAN TEMP/S: 0 - 32 °C (32 - 90 °F)
INT/A TEMP SE: More than 0 °C (32 °F)
5. Select "EVAP SML LEAK P0442" of "EVAPORATIVE SYSTEM" in "DTC WORK SUPPORT" mode with CONSULT-II. Follow the instruction displayed.
NOTE: If the engine speed cannot be maintained within the range displayed on the CONSULT-II screen, Initial Inspection (Basic Inspection).
6. Make sure that "OK" is displayed.
If "NG" is displayed, refer to Diagnostic Strategies
NOTE: Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve properly.
With GST
NOTE: Be sure to read the explanation of "Driving Pattern" before driving vehicle.
1. Start engine.
2. Drive vehicle according to "Driving Pattern".
3. Stop vehicle.
4. Select "MODE 1" with GST.
- If SRT of EVAP system is not set yet, go to the following step.
- If SRT of EVAP system is set, the result will be OK.
5. Turn ignition switch OFF and wait at least 5 seconds.
6. Start engine.
It is not necessary to cool engine down before driving.
7. Drive vehicle again according to the "Driving Pattern".
8. Stop vehicle.
9. Select "MODE 3" with GST.
- If P0442 is displayed on the screen, go to "Diagnostic Procedure" below.
- If P0441 is displayed on the screen, go to "Diagnostic Procedure" for "DTC P0441".
- If P0442 and P0441 are not displayed on the screen, go to the following step.
10. Select "MODE 1" with GST.
- If SRT of EVAP system is set, the result will be OK.
- If SRT of EVAP system is not set, go to step 6.
Diagnostic Procedure