Intake Door
Inspection Flow:
TROUBLE DIAGNOSIS PROCEDURE FOR INTAKE DOOR MOTOR
CONTROL SYSTEM OUTPUT COMPONENTS
Intake Door Motor
The intake door motor is attached to the intake unit.
It rotates so that air is drawn from inlets set by the A/C control unit when the mode switch is set to the MAX A/C (recirculation) position. Motor rotation is conveyed to a rod which opens and closes the intake door.
Intake Door Motor Operation:
Intake Door Motor Operation
Step 1:
Step 2 - 4:
INTAKE DOOR MOTOR CIRCUIT
CONTROL LINKAGE ADJUSTMENT
Intake Door Motor
1. Connect the intake door motor harness connector before installing the intake door motor.
2. Turn ignition switch ON.
3. Select MAX A/C (REC) mode.
4. Install the intake door lever and the intake door motor.
5. Set the intake door rod in MAX A/C (REC) position and fasten door rod to holder.
6. Check that the intake door operates properly when MAX A/C (REC) mode is selected.