Diagnostic Procedure 6
DIAGNOSTIC PROCEDURE 6 / Without Scan ToolInspecting SRS malfunctioning parts by using "AIR BAG" warning lamp - Diagnosis mode
NOTE: SRS will not enter Diagnosis mode if no malfunction is detected in User mode.
1. Turn ignition switch ON.
2. After "AIR BAG" warning lamp lights for 7 seconds, turn ignition switch OFF within 1 second.
3. Wait more than 3 seconds.
4. Repeat steps 1 to 3 two times.
5. Turn ignition switch ON.
SRS is now in Diagnosis mode. "AIR BAG" warning lamp operates in Diagnosis mode.
Refer to Trouble Code Descriptions / "AIR-BAG" Warning Lamp Flash Code Chart(s).
Air Bag System