Do you have access to Mitchell1 Prodemand? If you are willing to share user/password (we can pay $250), please get in contact with us ASAP: email operation-charm [[at]] tuta.io or click to submit anonymously
With Manufacturer's Scan Tool
SELF-DIAGNOSIS PROCEDURE1. Turn ignition switch OFF.
2. Connect CONSULT-II to Data Link Connector.
3. Start engine.
4. Drive vehicle over 30 km/h (19 MPH) for at least one minute.
5. Stop vehicle with engine running and touch "START" on CONSULT-II screen.
6. Touch "ABS".
7. Touch "SELF DIAGNOSIS RESULTS".
- The screen shows the detected malfunction and how many times the ignition switch has been turned since the malfunction.
8. Make the necessary repairs following the diagnostic procedures.
9. After the malfunctions are repaired, erase the self-diagnostic results stored in the control unit by touching "ERASE".
10. Check ABS warning lamp, SLIP indicator lamp, TCS OFF indicator lamp for deactivation after driving vehicle over 30 km/h (19 MPH) for at least one minute.
NOTE: "SELF-DIAG RESULTS" screen shows the detected malfunction and how many times the ignition switch has been turned since the malfunction.
SELF-DIAGNOSTIC RESULTS MODE
*1: When "## ## SENSOR 2" is displayed, check power supply for TCS/ABS control unit in addition to wheel sensor circuit.
*2: When any diagnosis results is detested with "CAN COMM CIRCUIT" CAN communication circuit first.
DATA MONITOR PROCEDURE
1. Turn ignition switch OFF.
2. Connect CONSULT-II to data link connector.
3. Turn ignition switch ON.
4. Touch "START" on CONSULT-II screen.
5. Touch "ABS".
6. Touch "DATA MONITOR".
7. Touch "SETTING" on "SELECT MONITOR ITEM" screen.
8. Touch "START" on "SELECT MONITOR ITEM".
ACTIVE TEST PROCEDURE
- When conducting Active test, vehicle must be stationary
- When ABS warning lamp or SLIP indicator lamp stays on, never conduct Active test.
1. Turn ignition switch OFF.
2. Connect CONSULT-II to Data Link Connector.
3. Start engine.
4. Touch "START" on CONSULT-II screen.
5. Touch "ABS".
6. Touch "ACTIVE TEST".
7. Select active test item by touching screen.
8. Touch "START".
9. Carry out the active test by touching screen key.
DATA MONITOR MODE
ACTIVE TEST MODE
NOTE: Active test will automatically stop ten seconds after the test starts. (TEST IS STOPPED monitor shows ON.)
*: "ON" lasts for 1 to 2 seconds after touching screen, then it goes to "OFF".