Operation CHARM: Car repair manuals for everyone.

C1116


C1116 - STOP LAMP SW

Inspection 10 - Stop Lamp Switch System


1. CHECK SELF-DIAGNOSIS RESULT.





Check self-diagnosis results.
Is above displayed in self-diagnosis display items?

YES >> GO TO 2.
NO >> Inspection END.

2. CHECK CONNECTOR.
1. Disconnect the stop lamp switch connector E116 and ABS actuator and electric unit (control unit) connector E24 and check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or replace terminal.
2. Securely reconnect connectors.
3. Start engine.
4. Repeat pumping brake pedal carefully several times, then perform self-diagnosis again.

OK or NG?

OK >> Connector terminal contact is loose, damaged, open or shorted.
NG >> GO To 3.

3. CHECK STOP LAMP SWITCH CIRCUIT.








1. Turn ignition switch OFF and disconnect stop lamp switch connector E116 and ABS actuator and electric unit (control unit) connector E24.
2. Check continuity between stop lamp switch harness connector E116 and ABS actuator and electric unit (control unit) harness connector E24.

OK or NG?

OK >> Connect connectors and conduct a ABS actuator and electric unit (control unit) self-diagnosis.
NG >> Open or short in harness. Repair or replace harness.