Operation CHARM: Car repair manuals for everyone.

Diagnostic Procedure 7

DIAGNOSTIC PROCEDURE 7 / Without Scan Tool

Final checking after repairing SRS by using "AIR BAG" warning lamp - Diagnosis mode and User mode










1. After repairing SRS connect both battery cables.

2. Open driver's door.

3. Turn ignition switch "ON".

4. "AIR BAG" warning lamp operates in Diagnosis mode as follows:

NOTE: When diagnosis sensor unit is replaced with new one, "AIR BAG" warning lamp will operate in User mode. Checking "AIR BAG" warning lamp operation in Diagnosis mode is not required. Go to step 6.

5. If "AIR BAG" warning lamp operates as shown in No. 1 in chart, turn ignition switch "OFF" to reset from Diagnosis mode to User mode and to erase the memory of the malfunction. Then go to step 6.

If "AIR BAG" warning lamp operates as shown in No. 2 or No. 3 in chart, the malfunctioning part is not repaired completely, or another malfunctioning part is detected. Go to "DIAGNOSTIC PROCEDURE 6", and repair malfunctioning part completely.
Diagnostic Procedure 6


6. Turn ignition switch "ON". "AIR BAG" warning lamp operates in User mode. Compare "AIR BAG" warning lamp operation to the chart.

NOTE: If switching Diagnosis mode to User mode is required while malfunction is being detected, turn ignition switch as follows:

7. Turn ignition switch "ON".

8. After "AIR BAG" warning lamp lights for 7 seconds, turn ignition switch "OFF".

9. Wait more than 3 seconds.

10. Repeat steps 1 to 3 three times.

11. Turn ignition switch "ON".