Automatic Air Conditioner
Magnet Clutch CircuitSYSTEM DESCRIPTION
Front air control controls compressor operation by ambient temperature and signal from ECM.
Low Temperature Protection Control
Front air control will turn the compressor ON or OFF as determined by a signal detected by ambient sensor.
When ambient temperature is greater than -2 °C (28 °F), the compressor turns ON. The compressor turns OFF when ambient temperature is less than -5 °C (23 °F).