ABS Actuator and Electric Unit (Control Unit) Power and Ground Systems
ABS Actuator and Electric Unit (Control Unit) Power and Ground SystemsINSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is the above displayed in the self-diagnosis display items?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Disconnect ABS actuator and electric unit (control unit) connector, check terminal to see if it is deformed, disconnected, loose, etc., and if there is an error, repair or replace the terminal.
2. Securely reconnect the connector and then perform self-diagnosis.
Is the result of self-diagnosis normal?
YES >> The connector terminal contact is loose, damaged, open or shorted.
NO >> GO TO 3.
3. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER AND GROUND CIRCUIT
Disconnect ABS actuator and electric unit connector E51. Check continuity and voltage between connector terminals and ground.
OK or NG
OK >> Check battery (terminal looseness, power drop, etc.) Error. If there is an error, make repairs.
NG >> Corresponding harness circuit error. Repair the circuit.