Operation CHARM: Car repair manuals for everyone.

Active Test

Active Test

CAUTION:
^ Do not perform active test while driving.
^ Make sure to completely bleed air from the brake system.
^ The ABS and brake warning lamps turn on during the active test.

OPERATION PROCEDURE
1. Connect the CONSULT-II and CONVERTER to the data link connector and start the engine.

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.

2. Touch "START (NISSAN BASED VHCL)" on the display screen.
3. Touch "ABS". If ABS is not indicated, go to GI-39, "CONSULT-II Data Link Connector (DLC) Circuit". Electrical Diagrams
4. Touch "ACTIVE TEST".





5. The test item selection screen is displayed.
6. Touch necessary test item.
7. With the "MAIN SIGNALS" display shown in reverse, touch "START".
8. The "ACTIVE TEST" screen will be displayed, so conduct the following test.

NOTE:
^ When the active test is conducted while depressing the pedal, the pedal depression amount will change, but this is normal.
^ Approximately 10 seconds after the operation is begun, "TEST STOP" will be displayed.
^ To conduct a retest after "TEST STOP" is displayed, touch "BACK" and conduct the from the step 6.

TEST ITEM
Solenoid valve

CAUTION: The example shown is for the front right wheel. The procedure for the other wheels is the same as given below.





For ABS solenoid valve, touch "UP", "KEEP", and "DOWN".Then use screen monitor to check that solenoid valve operates as shown in Solenoid Valve Operation Chart. Refer to "Solenoid Valve Operation Chart".





ABS Motor





Touch "ON", "OFF" on the display screen and make sure the ABS motor relay is operating as shown in the table.