Air Bag Control Module: Service and Repair
DIAGNOSIS SENSOR UNITRemoval and Installation
REMOVAL
CAUTION: Before servicing SRS, turn the ignition switch off, disconnect both battery cables and wait at least 3 minutes.
1. Disconnect each harness connector for the air bag module and seat belt pre-tensioner.
2. Remove center console.
3. Disconnect diagnosis sensor unit connector.
4. Remove fixing bolts from the diagnosis sensor unit.
Hex bolt Torque: 24.5 N.m (2.5 kg-m, 18 ft-lb)
Ground bolt Torque: 6.9 N.m (0.7 kg-m, 61 in-lb)
CAUTION:
- Do not use old bolts. Replace with new ones.
- Check diagnosis sensor unit bracket to ensure it is free of deformities, dents, cracks or rust. If it shows any visible signs of damage, replace with new one.
- Replace diagnosis sensor unit if it has been dropped or sustained an impact.
INSTALLATION
Install in the reverse order of removal.
CAUTION:
- Check the diagnosis sensor unit for proper installation.
- After replacement of diagnosis sensor unit, perform self-diagnosis to make sure that no malfunction is detected. Refer to SRS-21, "SRS Operation Check". [1][2]Component Tests and General Diagnostics