4: Hazard Warning Lamp Flashes When Ignition Switch Is Turned on

Inspection 4: Hazard Warning Lamp Flashes When Ignition Switch Is Turned On

DIAGNOSTIC PROCEDURE
1. CHECK GROUND CIRCUIT








1. Disconnect BCM connector M20.
2. Check continuity between BCM harness connector M20 terminal 67 and ground.
OK or NG
OK >> Replace BCM.