Refrigerant Pressure Sensor / Switch: Service and Repair
Exploded View MTC-97 (Part 1):
Exploded View MTC-97 (Part 2):
Components
Removal and Installation for Refrigerant Pressure Sensor
REMOVAL
1. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".
2. Disconnect the refrigerant pressure sensor harness connector and remove the refrigerant pressure sensor from the condenser.
CAUTION: Be careful not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal. Refer to Exploded View MTC-97.
CAUTION:
- Be careful not to damage the condenser fins.
- Replace the O-ring of the refrigerant pressure sensor with a new one, then apply compressor oil to it for installation.
- After charging refrigerant, check for leaks.