King Cab


DOOR SWITCH - KING CAB





Description
Detects door open/close condition.




Component Function Check
1.CHECK FUNCTION
With CONSULT-III
Check door switches in Data Monitor mode with CONSULT-III.





Is the inspection result normal?
YES - Door switch is OK.
NO - SEE Diagnosis Procedure.




Diagnosis Procedure
Regarding Wiring Diagram information, Wiring Diagram - King Cab.
1.CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-III
Check door switches ("DOOR SW-DR", "DOOR SW-AS") in DATA MONITOR mode with CONSULT-III. CONSULT-III Function.
- When any doors are open:






- When any doors are closed:






Without CONSULT-III
Check voltage between BCM connector M18 or M19 terminals 12, 47 and ground.










Is the inspection result normal?
YES - Door switch circuit is OK.
NO - GO TO 2
2.CHECK BCM OUTPUT VOLTAGE
1. Turn ignition switch OFF.
2. Disconnect door switches.





3. Check voltage between BCM connector M18, M19 terminals 12, 47 and ground.






Is the inspection result normal?
YES - GO TO 3
NO - Replace BCM. Service and Repair.
3.CHECK DOOR SWITCH CIRCUIT
1. Disconnect BCM.
2. Check continuity between door switch connector D213 (Front LH), D314 (Front RH) terminal 2, D211
(Rear upper LH), D312 (Rear upper RH), D212 (Rear lower LH), D313 (Rear lower RH) terminal 1 and BCM connector M18, M19 terminals 12, and 47.











3. Check continuity between door switch connector D213 (Front
LH), D314 (Front RH) terminal 2, D211 (Rear upper LH), D312
(Rear upper RH), D212 (Rear lower LH), D313 (Rear lower RH) terminal 1 and ground.






Is the inspection result normal?
YES - GO TO 4
NO - Repair or replace harness.
4.CHECK DOOR SWITCHES GROUND CIRCUIT
Check continuity between door switch connector D213 (Front LH), D314 (Front RH) terminal 3, D211 (Rear upper LH), D312 (Rear upper RH), D212 (Rear lower LH), D313 (Rear lower RH) terminal 2 and ground.











Is the inspection result normal?
YES - GO TO 5
NO - Repair or replace harness.
5.CHECK DOOR SWITCHES
Check continuity between door switch terminals.










Is the inspection result normal?
YES - Check condition of harness and connector.
NO - Replace door switch.