Daytime Light Relay Circuit
DAYTIME LIGHT RELAY CIRCUIT
Description
The BCM sends a daytime light request to the IPDM E/R via the CAN communication lines. The power flows backward through fuse 45 located in IPDM E/R to daytime light relay 1 and LH high beam lamp to IPDM E/R, through the high beam fuses, through the RH high beam lamp and on to ground. The high beam lamps are wired in series which causes them to illuminate at a reduced intensity.
Diagnosis Procedure
Regarding Wiring Diagram information, [1][2]Daytime Running Lamp.
1. CHECK DAYTIME LIGHT RELAY 1 FUSE
1.Turn the ignition switch OFF.
2.Check that the following fuse is not open.
Is the fuse open?
YES- Replace the fuse after repairing the affected circuit.
NO- GO TO 2
2. CHECK IPDM E/R OUTPUT SIGNAL
1.Turn the ignition switch OFF.
2.Disconnect the daytime light relay 1 connector.
3.Turn the ignition switch ON.
4.Check the voltage between the daytime light relay 1 harness connector and ground.
Is battery voltage present?
YES- GO TO 3
NO- GO TO 5
3. CHECK DAYTIME LIGHT RELAY 1 CIRCUIT
1.Turn the ignition switch OFF.
2.Disconnect IPDM E/R connector E122.
3.Check continuity between the IPDM E/R harness connector and the daytime light relay 1 harness connector.
4.Check continuity between the daytime light relay 1 harness connector and ground.
Is the measurement value normal?
YES- GO TO 4
NO- Repair the harnesses or connectors.
4. CHECK DAYTIME LIGHT RELAY 1
Check daytime light relay 1. .
Is the inspection result normal?
YES- Check headlamp (HI) circuit. If OK, replace IPDM E/R. Service and Repair. If NG, Headlamp (HI) Circuit.
NO- Replace daytime light relay1.
5. CHECK DAYTIME LIGHT RELAY CIRCUIT FOR OPEN
1.Turn the ignition switch OFF.
2.Disconnect IPDM E/R connector E119.
3.Check continuity between the IPDM E/R harness connector and the daytime light relay 1 harness connector.
Does continuity exist?
YES- Replace IPDM E/R. Service and Repair.
NO- Repair the harnesses or connectors.
Component Inspection
1. CHECK DAYTIME LIGHT RELAY 1
1.Turn ignition switch OFF.
2.Remove daytime light relay 1.
3.Check the continuity between daytime light relay 1 terminals under the following conditions.
Is the inspection result normal?
YES- Inspection End.