The Door Open Warning Continues Displaying, Or Does Not Display
THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT DISPLAY
Description
- The door ajar warning is displayed even though all of the doors and the trunk are closed.
- The door ajar warning is not displayed even though a door or the trunk is ajar.
Diagnosis Procedure
1. CHECK BCM INPUT SIGNAL
Check the BCM input signal. Refer to "Component Function Check" Door Switch.
Is the inspection result normal?
YES- GO TO 2.
NO- GO TO 3.
2. CHECK COMBINATION METER INPUT SIGNAL
Select the METER/M&A Data Monitor and check the DOOR W/L monitor value while opening and closing doors.
DOOR W/L
Door open : On
Door closed : Off
Is the inspection result normal?
YES- Replace combination meter. Refer to "Removal and Installation" Service and Repair.
NO- Replace BCM. Refer to "Removal and Installation" Service and Repair.
3. CHECK DOOR SWITCH SIGNAL CIRCUIT
Check the door switch signal circuit. Refer to "Diagnosis Procedure" Door Switch.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace harness or connectors.
4. CHECK DOOR SWITCH
Perform a unit check for the door switch. Refer to "Component Inspection" Door Switch.
Is the inspection result normal?
YES- Replace combination meter. Refer to "Removal and Installation" Service and Repair.
NO- Replace applicable door switch. Refer to "Removal and Installation" Service and Repair.