LH & RH Front Anti-Pinch
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement
INITIALIZATION PROCEDURE
1.Disconnect battery minus terminal or power window main switch connector. Reconnect it after a minute or more.
2.Turn ignition switch ON.
3.Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
4.Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 4 seconds or more.
5.Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
1.Fully open the door window.
2.Place a piece of wood near fully closed position.
3.Close door glass completely with AUTO-UP.
- Check that glass lowers for approximately 150 mm (5.91 in.) or 2 seconds without pinching piece of wood and stops.
- Check that glass does not rise when operating the power window main switch while lowering.
CAUTION:
- Do not check with hands and other part of body because they may be pinched. Do not get pinched.
- Check that AUTO-UP operates before inspection when system initialization is performed.
- It may switch to fail-safe mode if open/close operation is performed continuously. Perform initial setting in that situation. Refer to "Fail-Safe" Power Window Main Switch.
- Perform initial setting when auto-up operation or anti-pinch function does not operate normally.
- Finish initial setting. Otherwise, next operation cannot be done.
1.Auto-up operation
2.Anti-pinch function
3.Retained power operation when ignition switch is OFF.