Electrical Connections and Circuits
PRIMARY CONNECTIONSFully release connector locks prior to disconnecting. Ensure connectors are fully seated and all insulators and shields are in place when reinstalling.
CAUTIONS:
^ Never connect or disconnect electrical connections with the ignition switch in the "ON" position unless specifically directed to do so in a test procedure.
^ Do not use a self powered test lamp to check continuity.
^ Do not create any arcing to check the continuity of a circuit.
IGNITION SECONDARY CONNECTORS
CAUTIONS:
^ Never pierce ignition leads or insulator boots to connect timing lights or analyzers. Use proper adapters.
^ When removing a spark plug wire, twist the boot one quarter turn and pull on the boot only, never the lead itself.