Blower Switch Pop (High Setting to Off)
Fig. 2 For Blower Switch Pop, Connect As Shown.:
Install a diode (diode number IN4001, or the equivalent diode to withstand a 50V inverse peak voltage) from the high speed switch wire (orange) to ground on the high speed blower relay under the hood.