Operation CHARM: Car repair manuals for everyone.

Charging Station Method

Tool Required:

^ J 23500-01 Charging Station

Follow the charging station instructions provided with the charging station with the following exceptions:

1. Do not connect the high-pressure line to the air conditioning system.

2. Keep the high-pressure valve on the charging station closed at all times.

3. Perform the entire evacuation and charging procedure through the accumulator low side pressure service fining.

4. Following these procedures will prevent the high-pressure side from being subjected to the charging station if an error in valve sequence is made during compressor operation.