Electrical Specifications
RESISTANCE VALUESTCC Apply Solenoid at 20°C (68°F) 20-30 Ohms
TCC Apply Solenoid at 88°C (190°F) 23-50 Ohms
PWM/MOD Solenoid at 20°C (68°F) 10-15 Ohms
PWM/MOD Solenoid at 88°C (190°F) 11-25 Ohms
Shift "A" & "B" Solenoid at 20°C (68°F) 20-30 Ohms
Shift "A" & "B" Solenoid at 88°C (190°F) 23-50 Ohms
Temperature Switch (vehicles with Traction Control only) normally closed up to 156-164°C (313-327°F), then an open circuit and recloses on a temperature decrease at 149°C (300°F).
AMPERAGE DRAW
Amperage draw for the VCC, Shift "A" & "B" solenoids will be from about 0.5 to 0.8 Amps.