Operation CHARM: Car repair manuals for everyone.

Using Charging Station J-23500-01 or Equivalent

Refer to Specifications / Capacities section for refrigerant capacities. Capacity Specifications

Use instructions provided with charging station with the following exceptions:
1. Do not connect high pressure line to A/C system.
2. Always keep high pressure valve closed on charging station.
3. Perform all evacuation and charging through low side pressure service fitting.
Use of these procedures will prevent charging station from being accidentally exposed to high side system pressure.