Blower Motor Replacement - Auxiliary (Without E59)
REMOVAL PROCEDURE1. Remove the accessory panel.
2. Remove the shelf carrier.
3. Disconnect the auxiliary blower motor electrical connector.
4. Disconnect the auxiliary blower motor resistor electrical connector.
5. Disconnect the auxiliary air temperature actuator electrical connector.
6. Remove the auxiliary blower motor mounting screws.
7. Remove the auxiliary blower motor from the blower motor housing.
INSTALLATION PROCEDURE
1. Install the auxiliary blower motor to the blower motor housing.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the auxiliary blower motor mounting screws.
Tighten
Tighten the screws to 1.6 N.m (14 lb in).
3. Connect the auxiliary air temperature actuator electrical connector.
4. Connect the auxiliary blower motor resistor electrical connector.
5. Connect the auxiliary blower motor electrical connector.
6. Install the shelf carrier.
7. Install the accessory panel.
"For a description of the RPO Code(s) shown in this article or any of the images therein, refer to the RPO Code List found at Vehicle/Application ID". RPO Codes