Heater Heats Continuously and Can No Longer Be Regulated
Heater heats continuously and can no longer be regulated
Interruption in sensor series. Check outside sensor, interior sensor, and mixing chamber sensor.
Remove control switch and pull plug A.
Outer sensor: Connect ohmmeter with term.9 and ground
Reading:
at 0°C - 34 kohm ± 10%
at 10°C - 20 kohm ± 10%
at 25°C - 10 kohm ± 10%
Interior sensor:Connect ohmmeter with term.2 and ground
Reading: As for outside sensor
Mixing chamber sensor: Connect with term.1 and ground
Reading: As for outside sensor