Operation CHARM: Car repair manuals for everyone.

5.1 Preservation Charging

To prevent gassing, a simple charging device with maximum 0.05A and voltage limit 13.8V is sufficient for preservation /maintenance charging.

Preservation charging can be performed with battery connected at the following points:

- Jump start connection (928 only)
- Cigarette lighter
- Battery post