Flushing the Air-Conditioning System
Flushing the air-conditioning system
Note: Flushing the air-conditioning system serves the purpose of drying the circuit.
1. Evacuate.
2. Open the shut-off valve for high pressure (5) and the refrigerant outlet (11).
3. Allow refrigerant to flow in until a pressure of approx. 2 bar (absolute) is indicated.
4. Close shut-off valves 5 and 11.
5. Extract refrigerant again.
6. Evacuate.