OPERATING INSTRUCTIONS, PORSCHE SYSTEM TESTER 2:



GENERAL INFORMATION:
Use:
The Porsche System Tester 2 is a modular, portable diagnostic and measuring system. It can be used in any location to perform diagnostic tests on electronic control modules.

The Tester consists of a computer unit, a main memory, a hard disk, a VGA display panel, a nickel metal hydride battery and a measuring unit for measurement of current, voltage and resistance values.

The Porsche System Tester 2 can be operated with the built-in keys or using a connectable country-specific PS/2 keyboard (option).

Data and measured values can be printed out on one of the ten DIN A4 printers currently approved by Porsche.

The integrated LCD panel is used as the display. A monitor can also be connected (VGA connection).

If a printer or PS/2 keyboard is connected, the corresponding device type must be set under Configuration in the start-up screen.

The Tester thus can be used to check all systems that possess a diagnostic interface conforming with the ISO standard.

The following tasks can be performed:
- Reading out the control-module identification
- Reading out the fault memory
- Erasing the fault memory
- Testing the drive links
- Testing the input signals
- Reading out actual values
- Control module programming
- Current, voltage and resistance measurements

Malfunctions:
The Porsche System Tester 2 is a high-quality electronic device. In order to prevent damage to the unit due to improper use, please observe the operating instructions.

If the Tester no longer responds when any key is pressed, it must be set to a defined state:

1. Press the F1 and F8 keys in addition to the "ON/OFF" key.
2. Release the "ON/OFF" key, then the F1 and F8 keys.

Perform this switch off procedure only if the unit no longer responds when any key is pressed. This procedure can damage the hard disk under certain circumstances if it is performed during normal operation. It may be necessary to repeat input of data created within this diagnostic application.

Problems during operation are indicated to the user via the information line (info line). Example: "Diagnosis Card not inserted".

Tester Description:




Design of the Tester:

LCD Panel:




1. 9.5" LCD panel
monochrome
Resolution: 640 x 480 pixels (picture elements)

2. Keypad
2.1 Jump key
Used to change to the selection menu for control module-specific functions

2.2 On/Off switch

2.3 Print key
To print out data, measured values, screen display (hardcopy), working log and warranty log

2.4 This key is used to jump to the beginning

2.5 Used in combination with key 2.4 or 2.6 to control the brightness

2.6 This key is used to jump to the end

2.7 Used to move the cursor up

2.8 Used to move the cursor to the left

2.9 Used to move the cursor to the right and to select drive links, input signals and actual values

2.10 Used to move the cursor down

2.11 Enter key

2.12 Used to change the active screen part

2.13 Back key

2.14 Continue key

2.15 Escape key

3. Softkeys
Softkeys can be have different functions The functions are displayed at the bottom edge of the screen.