Adjusting the Footwell Flaps
1. Set motor to "Footwell flaps closed" end position: apply a voltage of 12 volts to pin 4 (negative) and pin 5 (positive) using two jumper leads until the motor is positioned in the end position. The drive lever now points towards the fresh air inlet.2. Set both footwell flaps to closed position. Engage linkage with lever and locate with clamp.