Operation CHARM: Car repair manuals for everyone.

Test Point 2

Fault Code 02
Door lock barrel closed, activated longer than 60 seconds.

NOTE: This fault can also be caused by incorrect operation (door lock actuated towards "Closed" direction for longer than 60 seconds).


1. Pull off plug I at the alarm control unit.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect plug connection X 12 (passenger's side).
4. Check the lines from the alarm control unit 1,pin 35 ,to the door lock modules for the ground shorts.
- Ohmmeter at alarm control unit plug I pin 35 and ground.
Display: infinity Ohms
5. Check the driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: infinity Ohms
Door lock actuated towards "Closed".
Display: < 5 Ohms
6. Check passenger's side door lock module switch contact.
- Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: infinity Ohms
Door lock actuated towards "Closed".
Display: < 5 Ohms