P0151
PO151
02 Sensor Circuit Low Voltage
Diagnostic conditions
- Battery positive voltage between 10 V and 16 V
- Oxygen sensing system active
- No secondary air
- No diagnosis of secondary air system
- No fuel tank ventilation
Possible cause of fault
- Short circuit to ground in signal wire
- Oxygen sensor faulty
- Control module faulty
Affected pins
DME control module connector II, pin 10 and oxygen sensor jack, bank 2, pin 3
DME control module connector II, pin 16 and oxygen sensor jack, bank 2, pin 4
Diagnosis/troubleshooting
NOTE: Do not use contact spray on the oxygen sensor plug connections as this may cause irreparable damage to the wiring (contamination of the oxygen sensor via the reference air channel).