DME 7.8
P1501
403 Throttle jacking unit, output stage - signal implausible
Diagnosis conditions
- Engine idling
Possible fault cause
- Short circuit in wiring harness
- DME control module output stage faulty
Affected terminals
Terminal I/7
NOTE: The vehicle is in emergency air function mode, i.e. the engine is turning at approx. 1200 rpm.
Diagnosis/troubleshooting