Heating and Air Conditioning: Specifications
Technical data for the air-conditioning system
Compressor type 7 SB 16
Refrigerant quantity 850 g refrigerant R 134a
Refrigerant oil in the compressor 195 +/- 15 cu.cm ND 8
NOTE: When installing the refrigerant lines, the screw connections and the O-rings must be wetted with refrigerant oil.
The refrigerant oil must be disposed of as special-category waste.