Oxygen Sensor Monitoring
Oxygen Sensor Monitoring
The oxygen sensors are monitored for:
- Operational readiness
- Connectivity
- Short circuit to B+
- Short circuit to ground
- Open circuit
- Aging of oxygen sensors via the control frequency and control position
Monitoring of Sensor Aging
Effect Of Period Duration On Emission Values:
Contamination or aging of the oxygen sensor affects the sensor voltage or period duration of the sensor signal and therefore has a negative influence on emission values.