Test Point 1
Checking The Actual Values
In the Actual values menu item, the current values of the following parameters can be read out and checked:
Test point 1
Tiptronic
- Ignition on
- Brake pedal actuated
- Engine off
PST2 display 100%
- Engine idling
PST2 display P,R,N: 70%
- Depends on gear engaged
PST2 display:
D:
1st gear 10%
2nd gear 20%
3rd gear 30%
4th gear 40%
5th gear 50%
M:
1st gear 15%
2nd gear 25%
3rd gear 35%
4th gear 45%
5th gear 55%
See also "Input signals", test point 1 and Technical information, Diagnosis/troubleshooting, Tiptronic.