Test Point 11
TEST POINT 11
Average Consumption
Note:
In the Actual Values menu item of the PST 2, the current values of the following parameters can be read out and checked.
- Engine off
- Select average consumption with on-board computer selector lever
PST 2 display: Tester display approximately equal to actual average consumption
- Switch off ignition
- Pull off plug II on the instrument cluster
- Disconnect plug on DmE control module (mE 5.2) or
- Disconnect plug IV on DmE control module (mE 7.2)
- Switch ignition on
- measure the voltage between instrument cluster plug II, pin 13 and ground
Display: 0 Volts
- Switch off ignition
- Ohmmeter on instrument cluster plug II, pin 13 and ground
Display: infinity
- Ohmmeter on instrument cluster plug II, pin 13 and plug on DmE control module (mE 5.2) pin 83 or
- Ohmmeter on instrument cluster plug II, pin 13 and on DmE control module plug IV, pin 33 (mE 7.2)
Display: < 5 ohms